La tarea solicitada aca, es.. agregar la System Board 6 al dominio B .
OJO, si las CPU son de distintas velocidades entre la SB actual y la que quiero agregar, hay que Rebootear.
Nota: Las IO Boards NO tienen flashprom para ser actualizados.
Una vez que inserte fisicamente la placa, vamos a agregar con Dynamic Reconfiguration la Nueva SB al dominio , con su paso previo de upgrade o downgrade como en este caso, del firmware de la placa.
e25k-sc0:sms-svc:1> showboards -v
Retrieving board information. Please wait.
.............
Location Pwr Type of Board Board Status Test Status Domain
-------- --- ------------- ------------ ----------- ------
SC0 On SC Main - -
SC1 On SC Spare - -
PS0 On PS-A196 - - -
PS1 On PS-A196 - - -
PS2 On PS-A196 - - -
PS3 On PS-A196 - - -
PS4 On PS-A196 - - -
PS5 On PS-A196 - - -
FT0 On FANTRAY - - -
FT1 On FANTRAY - - -
FT2 On FANTRAY - - -
FT3 On FANTRAY - - -
FT4 On FANTRAY - - -
FT5 On FANTRAY - - -
FT6 On FANTRAY - - -
FT7 On FANTRAY - - -
CS0 On CSB - - -
CS1 On CSB - - -
EX0 On EXB - - -
EX1 On EXB - - -
EX2 On EXB - - -
EX3 On EXB - - -
EX4 On EXB - - -
EX5 On EXB - - -
EX6 Off EXB - - -
EX7 Off EXB - - -
EX8 Off EXB - - -
EX9 On EXB - - -
EX10 On EXB - - -
EX11 On EXB - - -
EX12 On EXB - - -
EX13 On EXB - - -
EX14 On EXB - - -
EX15 On EXB - - -
EX16 Off EXB - - -
EX17 Off EXB - - -
IO0/C3V0 On C3V - - e25k-2-A
IO0/C5V0 On C5V - - e25k-2-A
IO0/C3V1 On C3V - - e25k-2-A
IO0/C3V2 On C3V - - e25k-2-A
IO1/C3V0 On C3V - - e25k-2-B
IO1/C5V0 On C5V - - e25k-2-B
IO1/C3V1 On C3V - - e25k-2-B
IO1/C3V2 On C3V - - e25k-2-B
IO2/C3V0 On C3V - - e25k-2-C
IO2/C5V0 On C5V - - e25k-2-C
IO2/C3V1 On C3V - - e25k-2-C
IO2/C3V2 On C3V - - e25k-2-C
IO3/C3V0 On C3V - - e25k-2-D
IO3/C5V0 On C5V - - e25k-2-D
IO1/C3V1 On C3V - - e25k-2-B
IO1/C3V2 On C3V - - e25k-2-B
IO2/C3V0 On C3V - - e25k-2-C
IO2/C5V0 On C5V - - e25k-2-C
IO2/C3V1 On C3V - - e25k-2-C
IO2/C3V2 On C3V - - e25k-2-C
IO3/C3V0 On C3V - - e25k-2-D
IO3/C5V0 On C5V - - e25k-2-D
IO3/C3V1 On C3V - - e25k-2-D
IO3/C3V2 On C3V - - e25k-2-D
IO4/C3V0 On C3V - - e25k-2-J
IO4/C5V0 On C5V - - e25k-2-J
IO4/C3V1 On C3V - - e25k-2-J
IO4/C3V2 On C3V - - e25k-2-J
IO9/C3V0 On C3V - - e25k-2-E
IO9/C5V0 On C5V - - e25k-2-E
IO9/C3V1 On C3V - - e25k-2-E
IO9/C3V2 On C3V - - e25k-2-E
IO10/C3V0 On C3V - - e25k-2-F
IO10/C5V0 On C5V - - e25k-2-F
IO10/C3V1 On C3V - - e25k-2-F
IO10/C3V2 On C3V - - e25k-2-F
IO11/C3V0 On C3V - - e25k-2-G
IO11/C5V0 On C5V - - e25k-2-G
IO11/C3V1 On C3V - - e25k-2-G
IO11/C3V2 On C3V - - e25k-2-G
IO12/C3V0 On C3V - - e25k-2-H
IO12/C5V0 On C5V - - e25k-2-H
IO12/C3V1 On C3V - - e25k-2-H
IO12/C3V2 On C3V - - e25k-2-H
IO13/C3V0 On C3V - - e25k-2-H
IO13/C5V0 On C5V - - e25k-2-H
IO13/C3V1 On C3V - - e25k-2-H
IO13/C3V2 On C3V - - e25k-2-H
IO14/C3V0 On C3V - - I
IO14/C5V0 On C5V - - I
IO14/C3V1 On C3V - - I
IO14/C3V2 On C3V - - I
IO15/C3V0 Off Unknown - - Isolated
IO15/C5V0 Off Unknown - - Isolated
IO15/C3V1 Off Unknown - - Isolated
IO15/C3V2 Off Unknown - - Isolated
SB0 On V3CPU Active Passed e25k-2-A
SB1 On V3CPU Active Passed e25k-2-B
SB2 On V3CPU Active Passed e25k-2-C
SB3 On V3CPU Active Passed e25k-2-D
SB4 On V3CPU Active Passed e25k-2-J
SB5 On V3CPU Active Passed e25k-2-E
SB6 Off V3CPU Available Unknown Isolated
SB7 - Empty Slot Available - Isolated
SB8 - Empty Slot Available - Isolated
SB9 On V3CPU Active Passed e25k-2-E
SB10 On V3CPU Active Passed e25k-2-F
SB11 On V3CPU Active Passed e25k-2-G
SB12 On V3CPU Active Passed e25k-2-H
SB13 On V3CPU (COD) Active Passed e25k-2-H
SB14 On V3CPU Active Passed I
SB15 On V3CPU Active Passed e25k-2-A
SB16 - Empty Slot Available - Isolated
SB17 - Empty Slot Available - Isolated
IO0 On HPCI+ Active Passed e25k-2-A
IO1 On HPCI+ Active Passed e25k-2-B
IO2 On HPCI+ Active Passed e25k-2-C
IO3 On HPCI+ Active Passed e25k-2-D
IO4 On HPCI+ Active Passed e25k-2-J
IO5 - Empty Slot Available - Isolated
IO6 - Empty Slot Available - Isolated
IO7 - Empty Slot Available - Isolated
IO8 - Empty Slot Available - Isolated
IO9 On HPCI+ Active Passed e25k-2-E
IO10 On HPCI+ Active Passed e25k-2-F
IO11 On HPCI+ Active Passed e25k-2-G
IO12 On HPCI+ Active Passed e25k-2-H
IO13 On HPCI+ Active Passed e25k-2-H
IO14 On HPCI+ Active Passed I
IO15 Off HPCI+ Available Unknown Isolated
IO16 - Empty Slot Available - Isolated
IO17 - Empty Slot Available - Isolated
e25k-sc0:sms-svc:2>
Primero Enciendo el Expander, sino falla el encedido de la SB.
Primero Enciendo el Expander, sino falla el encedido de la SB.
e25k-sc0:sms-svc:3> poweron EX6
e25k-sc0:sms-svc:4>
e25k-sc0:sms-svc:4> poweron SB6
e25k-sc0:sms-svc:5> showboards
Retrieving board information. Please wait.
..............................
Location Pwr Type of Board Board Status Test Status Domain
-------- --- ------------- ------------ ----------- ------
SB0 On V3CPU Active Passed e25k-2-A
SB1 On V3CPU Active Passed e25k-2-B
SB2 On V3CPU Active Passed e25k-2-C
SB3 On V3CPU Active Passed e25k-2-D
SB4 On V3CPU Active Passed e25k-2-J
SB5 On V3CPU Active Passed e25k-2-E
SB6 On V3CPU Available Unknown Isolated
SB7 - Empty Slot Available - Isolated
SB8 - Empty Slot Available - Isolated
SB9 On V3CPU Active Passed e25k-2-E
SB10 On V3CPU Active Passed e25k-2-F
SB11 On V3CPU Active Passed e25k-2-G
SB12 On V3CPU Active Passed e25k-2-H
SB13 On V3CPU Active Passed e25k-2-H
SB14 On V3CPU Active Passed I
SB15 On V3CPU Active Passed e25k-2-A
SB16 - Empty Slot Available - Isolated
SB17 - Empty Slot Available - Isolated
IO0 On HPCI+ Active Passed e25k-2-A
IO1 On HPCI+ Active Passed e25k-2-B
IO2 On HPCI+ Active Passed e25k-2-C
IO3 On HPCI+ Active Passed e25k-2-D
IO4 On HPCI+ Active Passed e25k-2-J
IO5 - Empty Slot Available - Isolated
IO6 - Empty Slot Available - Isolated
IO7 - Empty Slot Available - Isolated
IO8 - Empty Slot Available - Isolated
IO9 On HPCI+ Active Passed e25k-2-E
IO10 On HPCI+ Active Passed e25k-2-F
IO11 On HPCI+ Active Passed e25k-2-G
IO12 On HPCI+ Active Passed e25k-2-H
IO13 On HPCI+ Active Passed e25k-2-H
IO14 On HPCI+ Active Passed I
IO15 Off HPCI+ Available Unknown Isolated
IO16 - Empty Slot Available - Isolated
IO17 - Empty Slot Available - Isolated
e25k-sc0:sms-svc:6>
Ahora voy a actualizar el firmware, en este caso voy a hacer un downgrade, porque las placas que ya tenia el dominio estan con un nivel inferior
Ahora voy a actualizar el firmware, en este caso voy a hacer un downgrade, porque las placas que ya tenia el dominio estan con un nivel inferior
e25k-sc0:sms-svc:18> flashupdate -f /opt/SUNWSMS/hostobjs/sgcpu.flash SB6
Current System Board FPROM Information
========================================
V3CPU at SB6, FPROM 0:
POST 05/23/07 08:54:00 Release 5.20.6 Build 2.0 I/F 12
OBP 05/23/07 08:53:00 Release 5.20.6 Build 2.0
Ver 05/23/07 08:56:00 Release 5.20.6 Build 2.0
V3CPU at SB6, FPROM 1:
POST 05/23/07 08:54:00 Release 5.20.6 Build 2.0 I/F 12
OBP 05/23/07 08:53:00 Release 5.20.6 Build 2.0
Ver 05/23/07 08:56:00 Release 5.20.6 Build 2.0
Flash Image Information
==========================
POST 04/04/06 17:32:00 Release 5.20.0 Build 15.1 I/F 12
OBP 04/04/06 17:31:00 Release 5.20.0 Build 15.1
Ver 04/04/06 17:33:00 Release 5.20.0 Build 15.1
Do you wish to update the FPROM (yes/no)? yes
Update V3CPU at SB6, FPROM 0:
Erasing...
Done.
Writing and verifying ...
Done.
Update V3CPU at SB6, FPROM 1:
Erasing...
Done.
Writing and verifying ...
Done.
e25k-sc0:sms-svc:19>
e25k-sc0:sms-svc:23> addboard -d b SB6
assign SB6
.
assign SB6 done
poweron SB6
...
poweron SB6 done
test SB6
.....................
test SB6 done
connect SB6
....................
connect SB6 done
configure SB6
........
configure SB6 done
.
notify online SUNW_cpu/cpu192
notify online SUNW_cpu/cpu196
notify online SUNW_cpu/cpu193
notify online SUNW_cpu/cpu197
notify online SUNW_cpu/cpu194
notify online SUNW_cpu/cpu198
notify online SUNW_cpu/cpu195
notify online SUNW_cpu/cpu199
.
notify add capacity (8 cpus)
notify add capacity (4194304 pages)
notify add capacity SB6 done
e25k-sc0:sms-svc:24>