Bienvenidos

Todos estos pasos descriptos fueron probados en ambientes productivos

jueves, 24 de octubre de 2019

Borrar fallas en ILOM del T5-2

Este es el error que me da al intentar encender el T5 desde la ILOM
System faults or hardware configuration prevents power on

-> reset /System/
Are you sure you want to reset /System (y/n)? y
Performing reset on /System
reset: Target already stopped
Performing reset on /System failed

-> start /System/
Are you sure you want to start /System (y/n)? y
start: System faults or hardware configuration prevents power on.

-> start /SP/console
Are you sure you want to start /SP/console (y/n)? y

Serial console started.  To stop, type #.

Serial console stopped.

-> start /SP/faultmgmt/shell
Are you sure you want to start /SP/faultmgmt/shell (y/n)? y

faultmgmtsp>  fmadm faulty
------------------- ------------------------------------ -------------- --------
Time                UUID                                 msgid          Severity
------------------- ------------------------------------ -------------- --------
2019-10-23/04:16:05 7d375caa-0c4f-e9e6-cd92-eeb12b3d3bf6 SPT-8000-DH    Critical

Problem Status    : open
Diag Engine       : fdd 1.0
System
   Manufacturer   : Oracle Corporation
   Name           : SPARC T5-2
   Part_Number    : 33595397+1+1
   Serial_Number  : AK00315371

----------------------------------------
Suspect 1 of 1
   Fault class  : fault.chassis.voltage.fail
   Certainty    : 100%
   Affects      : /SYS/MB
   Status       : faulted

   FRU
      Status            : faulty
      Location          : /SYS/MB
      Manufacturer      : Oracle Corporation
      Name              : ASY,MB+TRAY+CPU,T5-2
      Part_Number       : 7302920
      Revision          : 02
      Serial_Number     : 465769T+1515UL0KGC
      Chassis
         Manufacturer   : Oracle Corporation
         Name           : SPARC T5-2
         Part_Number    : 33595397+1+1
         Serial_Number  : AK00313371

Description : A chassis voltage supply is operating outside of the
              allowable range.

Response    : The system will be powered off. The chassis-wide service
              required LED will be illuminated.

Impact      : The system is not usable until repaired. ILOM will not allow
              the system to be powered on until repaired.

Action      : Please refer to the associated reference document at
              http://support.oracle.com/msg/SPT-8000-DH for the latest
              service procedures and policies regarding this diagnosis.

faultmgmtsp> exit
-> set /SYS/MB clear_fault_action=true
Are you sure you want to clear /SYS/MB (y/n)? y
Set 'clear_fault_action' to 'true'

-> start /SP/faultmgmt/shell
Are you sure you want to start /SP/faultmgmt/shell (y/n)? y

faultmgmtsp> fmadm repair /SYS/MB
faultmgmtsp>  fmadm faulty
No faults found
faultmgmtsp> exit
->  start /SYS
Are you sure you want to start /SYS (y/n)? y
Starting /SYS

->
-> start /HOST/console
Are you sure you want to start /HOST/console (y/n)? y

Serial console started.  To stop, type #.

Serial console started.  To stop, type #.
2019-10-23 12:09:57  0:00:0> NOTICE:  Initializing MCU 0 Memory Link 0
2019-10-23 12:10:13  0:00:0> NOTICE:  Initializing MCU 0 Memory Link 1
2019-10-23 12:10:30  0:00:0> NOTICE:  Initializing MCU 1 Memory Link 0
2019-10-23 12:10:47  0:00:0> NOTICE:  Initializing MCU 1 Memory Link 1
2019-10-23 12:11:03  0:00:0> NOTICE:  Initializing MCU 2 Memory Link 0
2019-10-23 12:11:20  0:00:0> NOTICE:  Initializing MCU 2 Memory Link 1
2019-10-23 12:11:37  0:00:0> NOTICE:  Initializing MCU 3 Memory Link 0
2019-10-23 12:11:53  0:00:0> NOTICE:  Initializing MCU 3 Memory Link 1
2019-10-23 12:12:13  0:00:0> NOTICE:  Pausing for 120 seconds for Coherence Link tuning
2019-10-23 12:14:13  0:00:0> NOTICE:  Found optimal settings
2019-10-23 12:15:37  0:00:0> NOTICE:  Booting config = ldom-22102018
[CPU 00:00:0] Hypervisor version: @(#)Hypervisor 1.15.1.a 2015/09/09 12:51
2019-10-23 12:04:39      SP> NOTICE:  Start Host in progress: Step 5 of 7
2019-10-23 12:04:39      SP> NOTICE:  Start Host in progress: Step 6 of 7
NOTICE: Entering OpenBoot.
NOTICE: 2019-10-23 12:05:05      SP> NOTICE:  Start Host in progress: Step 7 of 7
Fetching Guest MD from HV.
NOTICE: Starting additional cpus.
NOTICE: Initializing LDC services.
NOTICE: Probing PCI devices.
NOTICE: Finished PCI probing.

SPARC T5-2, No Keyboard
Copyright (c) 1998, 2015, Oracle and/or its affiliates. All rights reserved.
OpenBoot 4.38.1, 32.0000 GB memory available, Serial #108418372.
Ethernet address 0:10:e0:76:55:44, Host ID: 86765544.



{0} ok