Borrar fallas en ILOM del T5-2

Este es el error que me da al intentar encender el T5 desde la ILOM
System faults or hardware configuration prevents power on

-> reset /System/
Are you sure you want to reset /System (y/n)? y
Performing reset on /System
reset: Target already stopped
Performing reset on /System failed

-> start /System/
Are you sure you want to start /System (y/n)? y
start: System faults or hardware configuration prevents power on.

-> start /SP/console
Are you sure you want to start /SP/console (y/n)? y

Serial console started.  To stop, type #.

Serial console stopped.

-> start /SP/faultmgmt/shell
Are you sure you want to start /SP/faultmgmt/shell (y/n)? y

faultmgmtsp>  fmadm faulty
------------------- ------------------------------------ -------------- --------
Time                UUID                                 msgid          Severity
------------------- ------------------------------------ -------------- --------
2019-10-23/04:16:05 7d375caa-0c4f-e9e6-cd92-eeb12b3d3bf6 SPT-8000-DH    Critical

Problem Status    : open
Diag Engine       : fdd 1.0
System
   Manufacturer   : Oracle Corporation
   Name           : SPARC T5-2
   Part_Number    : 33595397+1+1
   Serial_Number  : AK00315371

----------------------------------------
Suspect 1 of 1
   Fault class  : fault.chassis.voltage.fail
   Certainty    : 100%
   Affects      : /SYS/MB
   Status       : faulted

   FRU
      Status            : faulty
      Location          : /SYS/MB
      Manufacturer      : Oracle Corporation
      Name              : ASY,MB+TRAY+CPU,T5-2
      Part_Number       : 7302920
      Revision          : 02
      Serial_Number     : 465769T+1515UL0KGC
      Chassis
         Manufacturer   : Oracle Corporation
         Name           : SPARC T5-2
         Part_Number    : 33595397+1+1
         Serial_Number  : AK00313371

Description : A chassis voltage supply is operating outside of the
              allowable range.

Response    : The system will be powered off. The chassis-wide service
              required LED will be illuminated.

Impact      : The system is not usable until repaired. ILOM will not allow
              the system to be powered on until repaired.

Action      : Please refer to the associated reference document at
              http://support.oracle.com/msg/SPT-8000-DH for the latest
              service procedures and policies regarding this diagnosis.

faultmgmtsp> exit
-> set /SYS/MB clear_fault_action=true
Are you sure you want to clear /SYS/MB (y/n)? y
Set 'clear_fault_action' to 'true'

-> start /SP/faultmgmt/shell
Are you sure you want to start /SP/faultmgmt/shell (y/n)? y

faultmgmtsp> fmadm repair /SYS/MB
faultmgmtsp>  fmadm faulty
No faults found
faultmgmtsp> exit
->  start /SYS
Are you sure you want to start /SYS (y/n)? y
Starting /SYS

->
-> start /HOST/console
Are you sure you want to start /HOST/console (y/n)? y

Serial console started.  To stop, type #.

Serial console started.  To stop, type #.
2019-10-23 12:09:57  0:00:0> NOTICE:  Initializing MCU 0 Memory Link 0
2019-10-23 12:10:13  0:00:0> NOTICE:  Initializing MCU 0 Memory Link 1
2019-10-23 12:10:30  0:00:0> NOTICE:  Initializing MCU 1 Memory Link 0
2019-10-23 12:10:47  0:00:0> NOTICE:  Initializing MCU 1 Memory Link 1
2019-10-23 12:11:03  0:00:0> NOTICE:  Initializing MCU 2 Memory Link 0
2019-10-23 12:11:20  0:00:0> NOTICE:  Initializing MCU 2 Memory Link 1
2019-10-23 12:11:37  0:00:0> NOTICE:  Initializing MCU 3 Memory Link 0
2019-10-23 12:11:53  0:00:0> NOTICE:  Initializing MCU 3 Memory Link 1
2019-10-23 12:12:13  0:00:0> NOTICE:  Pausing for 120 seconds for Coherence Link tuning
2019-10-23 12:14:13  0:00:0> NOTICE:  Found optimal settings
2019-10-23 12:15:37  0:00:0> NOTICE:  Booting config = ldom-22102018
[CPU 00:00:0] Hypervisor version: @(#)Hypervisor 1.15.1.a 2015/09/09 12:51
2019-10-23 12:04:39      SP> NOTICE:  Start Host in progress: Step 5 of 7
2019-10-23 12:04:39      SP> NOTICE:  Start Host in progress: Step 6 of 7
NOTICE: Entering OpenBoot.
NOTICE: 2019-10-23 12:05:05      SP> NOTICE:  Start Host in progress: Step 7 of 7
Fetching Guest MD from HV.
NOTICE: Starting additional cpus.
NOTICE: Initializing LDC services.
NOTICE: Probing PCI devices.
NOTICE: Finished PCI probing.

SPARC T5-2, No Keyboard
Copyright (c) 1998, 2015, Oracle and/or its affiliates. All rights reserved.
OpenBoot 4.38.1, 32.0000 GB memory available, Serial #108418372.
Ethernet address 0:10:e0:76:55:44, Host ID: 86765544.



{0} ok

1 comentario:

  1. As claimed by Stanford Medical, It's really the one and ONLY reason this country's women live 10 years more and weigh 42 lbs lighter than we do.

    (Just so you know, it has NOTHING to do with genetics or some secret diet and really, EVERYTHING to "how" they are eating.)

    P.S, I said "HOW", and not "WHAT"...

    Tap this link to find out if this easy quiz can help you unlock your true weight loss potential

    ResponderEliminar